In the Linux kernel, the following vulnerability has been resolved:
ALSA: usb-audio: Fix NULL pointer dereference in snd_usb_mixer_controls_badd
In snd_usb_create_streams(), for UAC version 3 devices, the Interface
Association Descriptor (IAD) is retrieved via usb_ifnum_to_if(). If this
call fails, a fallback routine attempts to obtain the IAD from the next
interface and sets a BADD profile. However, snd_usb_mixer_controls_badd()
assumes that the IAD retrieved from usb_ifnum_to_if() is always valid,
without performing a NULL check. This can lead to a NULL pointer
dereference when usb_ifnum_to_if() fails to find the interface descriptor.
This patch adds a NULL pointer check after calling usb_ifnum_to_if() in
snd_usb_mixer_controls_badd() to prevent the dereference.
This issue was discovered by syzkaller, which triggered the bug by sending
a crafted USB device descriptor.
What the EG score is made of (scorer v4.0: the three questions the 0–10 score mixes, published apart · methodology)
- EG Severity
- Not assessed: no CVSS publishedA missing CVSS is not a severity of zero.
- EG Likelihood
- 0.2% within 30 daysSource: FIRST EPSS. FIRST's exploitation probability, not an EchelonGraph model.
- Confirmed exploitation
- None on record (CISA KEV, EG-KEV Tier 1)Reported apart from the likelihood: an observed fact, not a probability.
- EG Priority
- No SSVC decision: EchelonGraph has not assessed this CVECISA BOD 26-04: 14 days if the affected system is publicly exposed; Fix on system upgrade if it is not.Each input and its source, and whom BOD 26-04 binds: the BOD 26-04 block below.
BOD 26-04 (CISA's remediation timeline, Table 1)14 days if the affected system is publicly exposed; Fix on system upgrade if it is not.
The score's inputs: In CISA KEV no (CISA's KEV catalog) · Automatable no (CISA's BOD 26-04 default) · Technical impact total (CISA's BOD 26-04 default). Where an input reads “CISA's BOD 26-04 default”, no one has published it for this CVE, and CISA's implementation guidance says: “If “Automatable” and “Technical Impact” information items about a CVE ID are not available and the CVE ID is not in the KEV Catalog, CISA will treat its values as “no” and “total,” respectively, until CISA or a third party provides metadata about the CVE ID. CISA will always provide the Vulnrichment data for a CVE ID listed in the KEV Catalog.” Whether your system is publicly exposed is yours to answer. BOD 26-04 binds US Federal Civilian Executive Branch agencies; for anyone else it is CISA's published timeline, a reference rather than an obligation. The directive · how EchelonGraph applies it