In the Linux kernel, the following vulnerability has been resolved:
scsi: pm80xx: Fix array-index-out-of-of-bounds on rmmod
Since commit f7b705c238d1 ("scsi: pm80xx: Set phy_attached to zero when
device is gone") UBSAN reports:
UBSAN: array-index-out-of-bounds in drivers/scsi/pm8001/pm8001_sas.c:786:17
index 28 is out of range for type 'pm8001_phy [16]'
on rmmod when using an expander.
For a direct attached device, attached_phy contains the local phy id.
For a device behind an expander, attached_phy contains the remote phy
id, not the local phy id.
I.e. while pm8001_ha will have pm8001_ha->chip->n_phy local phys, for a
device behind an expander, attached_phy can be much larger than
pm8001_ha->chip->n_phy (depending on the amount of phys of the
expander).
E.g. on my system pm8001_ha has 8 phys with phy ids 0-7. One of the
ports has an expander connected. The expander has 31 phys with phy ids
0-30.
The pm8001_ha->phy array only contains the phys of the HBA. It does not
contain the phys of the expander. Thus, it is wrong to use attached_phy
to index the pm8001_ha->phy array for a device behind an expander.
Thus, we can only clear phy_attached for devices that are directly
attached.
What the EG score is made of (scorer v4.0: the three questions the 0–10 score mixes, published apart · methodology)
The EG score (7.8): severity, escalated by confirmed exploitation. This CVE's 7.8 is its impact severity (EG Severity), not escalated.
- EG Severity
- 7.8 HIGHCVSS-B, impact only: no KEV listing, EPSS or EG-KEV tier raises it.GitHub Security Advisory CVSS
- EG Likelihood
- 0.2% within 30 daysSource: FIRST EPSS. FIRST's exploitation probability, not an EchelonGraph model.
- Confirmed exploitation
- None on record (CISA KEV, EG-KEV Tier 1)Reported apart from the likelihood: an observed fact, not a probability.
- EG Priority
- SSVC Track at medium mission impactTrack at low or medium mission impact; Track* at high (mission-essential systems).CISA BOD 26-04: 14 days if the affected system is publicly exposed; Fix on system upgrade if it is not.Each input and its source, and whom BOD 26-04 binds: the SSVC and BOD 26-04 blocks below.
SSVC (CISA's decision table, applied by EchelonGraph)Track at low or medium mission impact; Track* at high (mission-essential systems).
A fix is available. Apply it within your standard update timelines.
Exploitation none (no CISA value, KEV listing or exploit code on record) · Automatable no (CISA's BOD 26-04 default) · Technical impact total (CISA's BOD 26-04 default). EchelonGraph holds no SSVC assessment of this CVE from CISA: none of these inputs is from Vulnrichment. EchelonGraph applied CISA's decision table to them; CISA publishes SSVC inputs and the table, not a decision for each CVE. Mission impact is CISA's Mission & Well-being decision point, and only you can judge it. CISA's table makes it high when Mission Prevalence is Essential — the vulnerable component "directly provides capabilities that constitute at least one MEF for at least one entity" (MEF: mission essential function) — or when Public Well-Being Impact is Irreversible: "multiple fatalities are likely", the cyber-physical system "is likely lost or destroyed", "extreme or serious externalities" are imposed on other parties, or social systems such as elections or the financial grid "are destabilized and potentially collapse". CISA's decision table
BOD 26-04 (CISA's remediation timeline, Table 1)14 days if the affected system is publicly exposed; Fix on system upgrade if it is not.
The score's inputs: In CISA KEV no (CISA's KEV catalog) · Automatable no (CISA's BOD 26-04 default) · Technical impact total (CISA's BOD 26-04 default). Where an input reads “CISA's BOD 26-04 default”, no one has published it for this CVE, and CISA's implementation guidance says: “If “Automatable” and “Technical Impact” information items about a CVE ID are not available and the CVE ID is not in the KEV Catalog, CISA will treat its values as “no” and “total,” respectively, until CISA or a third party provides metadata about the CVE ID. CISA will always provide the Vulnrichment data for a CVE ID listed in the KEV Catalog.” Whether your system is publicly exposed is yours to answer. BOD 26-04 binds US Federal Civilian Executive Branch agencies; for anyone else it is CISA's published timeline, a reference rather than an obligation. The directive · how EchelonGraph applies it