GHSA-9899-m83m-qhpjLowCVSS 3.3
Electron: USB device selection not validated against filtered device list
🔗 CVE IDs covered (1)
📋 Description
Impact
The select-usb-device event callback did not validate the chosen device ID against the filtered list that was presented to the handler. An app whose handler could be influenced to select a device ID outside the filtered set would grant access to a device that did not match the renderer's requested filters or was listed in exclusionFilters.
The WebUSB security blocklist remained enforced regardless, so security-sensitive devices on the blocklist were not affected. The practical impact is limited to apps with unusual device-selection logic.
Workarounds
There are no app side workarounds, you must update to a patched version of Electron.
Fixed Versions
41.0.0-beta.840.7.039.8.038.8.6
For more information
If there are any questions or comments about this advisory, send an email to [email protected]
🎯 Affected products4
- npm/electron:< 38.8.6
- npm/electron:>= 39.0.0-alpha.1, < 39.8.0
- npm/electron:>= 40.0.0-alpha.1, < 40.7.0
- npm/electron:>= 41.0.0-alpha.1, < 41.0.0-beta.8