In the Linux kernel, the following vulnerability has been resolved:
nfc: trf7970a: power down on startup RX gain failure
trf7970a_startup() powers up the device before applying the optional RX
gain reduction. If the register read or write fails, it returns without
undoing that power-up. Probe's unwind only drops the separate regulator
references acquired by probe, leaving the additional VIN enable from
startup unbalanced. The system resume caller also has no power-down on
this error.
Call trf7970a_power_down() before returning the RX gain error to deassert
the enable GPIOs, release the startup VIN reference and restore the
powered-off state. Runtime PM has not been enabled yet, so the full
shutdown helper is not appropriate here. Preserve the original SPI error.
This issue was identified during our ongoing static-analysis research while
reviewing kernel code.
What the EG score is made of (scorer v4.0: the three questions the 0–10 score mixes, published apart · methodology)
- EG Severity
- Not assessed: no CVSS publishedA missing CVSS is not a severity of zero.
- EG Likelihood
- 0.2% within 30 daysSource: FIRST EPSS. FIRST's exploitation probability, not an EchelonGraph model.
- Confirmed exploitation
- None on record (CISA KEV, EG-KEV Tier 1)Reported apart from the likelihood: an observed fact, not a probability.
- EG Priority
- No SSVC decision: EchelonGraph has not assessed this CVECISA BOD 26-04: 14 days if the affected system is publicly exposed; Fix on system upgrade if it is not.Each input and its source, and whom BOD 26-04 binds: the BOD 26-04 block below.
BOD 26-04 (CISA's remediation timeline, Table 1)14 days if the affected system is publicly exposed; Fix on system upgrade if it is not.
The score's inputs: In CISA KEV no (CISA's KEV catalog) · Automatable no (CISA's BOD 26-04 default) · Technical impact total (CISA's BOD 26-04 default). Where an input reads “CISA's BOD 26-04 default”, no one has published it for this CVE, and CISA's implementation guidance says: “If “Automatable” and “Technical Impact” information items about a CVE ID are not available and the CVE ID is not in the KEV Catalog, CISA will treat its values as “no” and “total,” respectively, until CISA or a third party provides metadata about the CVE ID. CISA will always provide the Vulnrichment data for a CVE ID listed in the KEV Catalog.” Whether your system is publicly exposed is yours to answer. BOD 26-04 binds US Federal Civilian Executive Branch agencies; for anyone else it is CISA's published timeline, a reference rather than an obligation. The directive · how EchelonGraph applies it