In the Linux kernel, the following vulnerability has been resolved:
wifi: p54: validate curve data length in the calibration curve converters
p54_convert_rev0() and p54_convert_rev1() read calibration curve
data from the device-supplied EEPROM entry using channel and
points-per-channel counts taken verbatim from that same entry, so
an entry that declares more data than it carries drives an
out-of-bounds read past the EEPROM buffer (verified with a KASAN
reproducer of the conversion loop). The sibling converters
p54_convert_output_limits() and p54_convert_db() already validate
their counts against the entry length; this path was missed.
Reject the entry when the counts do not fit in the entry data.
BOD 26-04 (CISA's remediation timeline, Table 1)14 days if the affected system is publicly exposed; Fix on system upgrade if it is not.
In CISA KEV no (CISA's KEV catalog) · Automatable no (CISA's BOD 26-04 default) · Technical impact total (CISA's BOD 26-04 default). Where an input reads “CISA's BOD 26-04 default”, no one has published it for this CVE, and CISA's implementation guidance says: “If “Automatable” and “Technical Impact” information items about a CVE ID are not available and the CVE ID is not in the KEV Catalog, CISA will treat its values as “no” and “total,” respectively, until CISA or a third party provides metadata about the CVE ID. CISA will always provide the Vulnrichment data for a CVE ID listed in the KEV Catalog.” Whether your system is publicly exposed is yours to answer. BOD 26-04 binds US Federal Civilian Executive Branch agencies; for anyone else it is CISA's published timeline, a reference rather than an obligation. The directive · how EchelonGraph applies it