In the Linux kernel, the following vulnerability has been resolved:
i3c: renesas: Check that the transfer is valid before accessing it
The Renesas I3C driver uses an asynchronous model to transfer data. It
prepares a struct renesas_i3c_xfer, enqueues it, and waits for completion.
The interrupt handler dequeues the transfer, updates/uses it, and signals
the waiting thread.
If the completion times out, the waiting thread dequeues the transfer and
free it. If an interrupt fires after that, the handler may access freed
memory, leading to crashes.
Check that the transfer is still valid before accessing it in the
interrupt handler. With it clear any status flags and disable all
the interrupts to avoid triggering the same interrupts again.
SSVC (CISA's decision table, applied by EchelonGraph)Track at low or medium mission impact; Track* at high (mission-essential systems).
A fix is available. Apply it within your standard update timelines.
Exploitation none (no CISA value, KEV listing or exploit code on record) · Automatable no (CISA's BOD 26-04 default) · Technical impact total (CISA's BOD 26-04 default). EchelonGraph holds no SSVC assessment of this CVE from CISA: none of these inputs is from Vulnrichment. EchelonGraph applied CISA's decision table to them; CISA publishes SSVC inputs and the table, not a decision for each CVE. Mission impact is CISA's Mission & Well-being decision point, and only you can judge it. CISA's table makes it high when Mission Prevalence is Essential — the vulnerable component "directly provides capabilities that constitute at least one MEF for at least one entity" (MEF: mission essential function) — or when Public Well-Being Impact is Irreversible: "multiple fatalities are likely", the cyber-physical system "is likely lost or destroyed", "extreme or serious externalities" are imposed on other parties, or social systems such as elections or the financial grid "are destabilized and potentially collapse". CISA's decision table
BOD 26-04 (CISA's remediation timeline, Table 1)14 days if the affected system is publicly exposed; Fix on system upgrade if it is not.
In CISA KEV no (CISA's KEV catalog) · Automatable no (CISA's BOD 26-04 default) · Technical impact total (CISA's BOD 26-04 default). Where an input reads “CISA's BOD 26-04 default”, no one has published it for this CVE, and CISA's implementation guidance says: “If “Automatable” and “Technical Impact” information items about a CVE ID are not available and the CVE ID is not in the KEV Catalog, CISA will treat its values as “no” and “total,” respectively, until CISA or a third party provides metadata about the CVE ID. CISA will always provide the Vulnrichment data for a CVE ID listed in the KEV Catalog.” Whether your system is publicly exposed is yours to answer. BOD 26-04 binds US Federal Civilian Executive Branch agencies; for anyone else it is CISA's published timeline, a reference rather than an obligation. The directive · how EchelonGraph applies it