In the Linux kernel, the following vulnerability has been resolved:
ALSA: FCP: Use a private URB for the notification endpoint
fcp_init_notify() used mixer->urb, which snd_usb_mixer_status_create()
allocates for the optional UAC2 status interrupt endpoint and mixer.c
kills, resubmits and frees. On a device with that endpoint,
fcp_init_notify()'s "already set up" early return fires on the status
URB and returns success without doing anything. No FCP notification
URB is submitted, and cmd_done is left zeroed because it is
initialised past that early return and nowhere else. fcp_init() then
issues init1_opcode and wait_for_completion_timeout() would crash
adding to the zeroed wait.head. fcp_cleanup_urb() would also kill and
free mixer.c's status URB.
Use a separate URB in fcp_data, and initialise cmd_done in
fcp_init_private() where fcp_data is allocated. fcp_init_notify() is
reached again after suspend via fcp_reinit(), and the URB kill path in
fcp_notify() completes cmd_done, leaving a stale count that would
satisfy the next command's wait before the device ACKs. Use
reinit_completion() to clear it.
What the EG score is made of (scorer v4.0: the three questions the 0–10 score mixes, published apart · methodology)
- EG Severity
- Not assessed: no CVSS publishedA missing CVSS is not a severity of zero.
- EG Likelihood
- 0.2% within 30 daysSource: FIRST EPSS (model v2026.06.15, score date 2026-10-24). FIRST's exploitation probability, not an EchelonGraph model.
- Confirmed exploitation
- None on record (CISA KEV, EG-KEV Tier 1)Reported apart from the likelihood: an observed fact, not a probability.
- EG Priority
- No SSVC decision: EchelonGraph has not assessed this CVECISA BOD 26-04: 14 days if the affected system is publicly exposed; Fix on system upgrade if it is not.Each input and its source: the BOD 26-04 block below.
BOD 26-04 (CISA's remediation timeline, Table 1)14 days if the affected system is publicly exposed; Fix on system upgrade if it is not.
In CISA KEV no (CISA's KEV catalog) · Automatable no (CISA's BOD 26-04 default) · Technical impact total (CISA's BOD 26-04 default). Where an input reads “CISA's BOD 26-04 default”, no one has published it for this CVE, and CISA's implementation guidance says: “If “Automatable” and “Technical Impact” information items about a CVE ID are not available and the CVE ID is not in the KEV Catalog, CISA will treat its values as “no” and “total,” respectively, until CISA or a third party provides metadata about the CVE ID. CISA will always provide the Vulnrichment data for a CVE ID listed in the KEV Catalog.” Whether your system is publicly exposed is yours to answer. BOD 26-04 binds US Federal Civilian Executive Branch agencies; for anyone else it is CISA's published timeline, a reference rather than an obligation. The directive · how EchelonGraph applies it