CVE-2026-104112

MEDIUMPre-NVD 6.86.8
EchelonGraph scoreLOW confidence

This medium-severity CVE scores 6.8 under a secondary CVSS source (NVD's own analysis pending). EPSS exploit-prediction score not yet available (the EPSS model rescores nightly; freshly-published CVEs typically appear within 48 hours). GitHub Security Advisory data not yet ingested — confidence will rise once GHSA publishes (typical lag: hours to days for open-source ecosystem CVEs; never for infrastructure-only CVEs).

Triggered by: NVD CVSS baseline
Sources: secondary
Trending — 3 sources updated this week
6.8EG
EchelonGraph verdictMonitorLow exploitation likelihood right now — keep watching.
  • Lower severity and no public exploit yet
CISA-KEV: Not listedEPSS PROB: —CVSS: 6.8Exploit: None knownExposed services: Not assessed

An upstream fix is merged but not yet released — mitigate (WAF / firewall / segmentation) until the release ships, then apply it.

A missing release of resources in the illumos name service cache daemon (nscd) allows a local user to exhaust kernel memory. The nscd door server procedure, switcher() in usr/src/cmd/nscd/nscd_frontend.c, does not close file descriptors that are passed with a door call but not used by the request, and the main nscd door at /var/run/name_service_door accepts passed descriptors from any user in its zone. Because nscd also runs with an unlimited file descriptor limit, an unprivileged local user, including one in a non-global zone, can repeatedly pass a descriptor to its zone's nscd in a door_call() loop, causing the file descriptor table of nscd to grow without bound in kernel memory. This causes a denial of service of nscd and can render processes in all zones on the host unresponsive. The flaw has existed since 2006 (illumos-gate commit cb5caa98), and affects any illumos distribution prior to illumos-gate commit af810a72.

CVSS v3
6.8
EG Score
6.8MEDIUMlow confidence
EG Risk
31
EG Risk 31/100CISA SSVC

EG Risk is EchelonGraph's 0–100 priority score: it fuses intrinsic severity with real-world exploitation and automatability so you can rank equal-severity CVEs and fix the most dangerous first. Higher = act sooner. Distinct from the 0–10 EG Score (severity).

How it’s computed
Severity68% × 45%
Exploitation0% × 40%
Automatability0% × 15%
CISA SSVC: Track at every mission impact level.
Action: An upstream fix is merged but not yet in a tagged release. Restrict network exposure of the affected system or apply the vendor's mitigation within your standard update timelines until it ships, then apply the release.
EPSS PROB
—
EPSS %ILE
—
KEV
Not listed

CISA SSVCTrack at every mission impact level.

An upstream fix is merged but not yet in a tagged release. Restrict network exposure of the affected system or apply the vendor's mitigation within your standard update timelines until it ships, then apply the release.

Exploitation none (CISA Vulnrichment) · Automatable no (CISA Vulnrichment) · Technical impact partial (CISA Vulnrichment). Mission impact is CISA's Mission & Well-being decision point, and only you can judge it: high means the affected system is essential to your organisation's mission, or its compromise could cause irreversible harm to people. CISA's decision table

Published

October 9, 2026

Last Modified

October 9, 2026

Advisory Details (3)

Auto-updated Oct 9, 2026
Upstream fix merged — awaiting tagged release. Sources: github_commit.
github_commit

commit af810a72c099 (illumos/illumos-gate)

Fix landed in illumos/illumos-gate commit af810a72c099 — awaiting tagged release

https://github.com/illumos/illumos-gate/commit/af810a72c09944e884ec695e8dbf1702a4f424ae
generic

Bug #18494: nscd: unbounded file descriptor allocation - illumos gate - illumos

https://illumos.org/issues/18494

Vendor Advisories for CVE-2026-104112(1)

These vendors published their own advisory mentioning this CVE — often with vendor-specific remediation steps + affected product lists not in NVD.

Weakness Classification(1)

MITRE Common Weakness Enumeration — the root-cause categories this CVE belongs to.

Data Freshness Timeline

(refreshed 8× in last 7d / 8× in last 30d)

Each row is a source pipeline that fetched or updated this CVE on that date, with what changed. For example, "NVD update" means NVD published or revised its analysis for this CVE; "MITRE cvelistV5" means we ingested or refreshed it from the CNA feed. Most recent first.

  1. 2026-10-09 17:35 UTCEG score recompute
  2. 2026-10-09 17:34 UTCGHSA enrichment
  3. 2026-10-09 16:54 UTCEG score recompute
  4. 2026-10-09 16:53 UTCGHSA enrichment
  5. 2026-10-09 15:32 UTCEG score recompute
  6. 2026-10-09 15:32 UTCGHSA enrichment
  7. 2026-10-09 14:29 UTCEG score recompute
  8. 2026-10-09 14:28 UTCMITRE cvelistV5first tracked

Frequently asked(4)

What is CVE-2026-104112?
CVE-2026-104112 is a medium vulnerability published on October 9, 2026. A missing release of resources in the illumos name service cache daemon (nscd) allows a local user to exhaust kernel memory. The nscd door server procedure, switcher() in usr/src/cmd/nscd/nscdfrontend.c, does not close file descriptors that are passed with a door call but not used by the request,…
When was CVE-2026-104112 disclosed?
CVE-2026-104112 was first published on October 9, 2026. EchelonGraph re-ingests CVE updates from NVD on a 2-hour cycle, so this page reflects the latest published state.
What is the CVSS score of CVE-2026-104112?
CVE-2026-104112 has a CVSS base score of 6.8 (a secondary CVSS source that NVD displays; NVD's own analysis pending). The EG score is currently aggregating — additional source signals are being incorporated as they become available..
How do I remediate CVE-2026-104112?
An upstream fix for CVE-2026-104112 has been merged but is not yet in a tagged release. Until it ships, restrict network exposure of the affected system or apply the vendor's mitigation, then update to the release that contains the fix. The vendor advisories EchelonGraph has for CVE-2026-104112 are linked in the Vendor Advisories panel on this page.

Dependency Blast Radius

Explore the affected products and dependency analysis for CVE-2026-104112

Explore →

Is Your Infrastructure Affected by CVE-2026-104112?

EchelonGraph automatically scans your cloud infrastructure and maps CVE exposure using blast radius analysis.