CVE-2025-7854

HIGHPre-NVD 8.88.8
EchelonGraph scoreMEDIUM confidence

Score 8.8 from GitHub Security Advisory (severity: HIGH) published 2025-07-19. a secondary CVSS source baseline 8.8; sources differ by 0.0.

Triggered by: GitHub Security Advisory CVSS
Sources: epss, ghsa, secondary
Elevated
8.8EG
EchelonGraph verdictPlan a fixSerious severity, but no confirmed exploitation yet.
  • High severity, but no confirmed exploitation yet
CISA-KEV: Not listedEPSS PROB: 1%CVSS: 8.8Exploit: Elevated riskExposed: 0

No vendor fix yet — apply a workaround or compensating control (WAF / firewall / segmentation) and watch for a patch.

A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.

CVSS v3
8.8
EG Score
8.8(medium)
EG Risk
56(Track)
EG Risk 56/100SSVC: Track

EG Risk is EchelonGraph's 0–100 priority score: it fuses intrinsic severity with real-world exploitation and automatability so you can rank equal-severity CVEs and fix the most dangerous first. Higher = act sooner. Distinct from the 0–10 EG Score (severity).

How it’s computed
Severity88% × 45%
Exploitation40% × 40%
Automatability0% × 15%
Action: Routine — remediate on your standard cadence.
EPSS PROB
1%
EPSS %ILE
62%
KEV
Not listed

Published

July 19, 2025

Last Modified

June 17, 2026

Related CVEs are temporarily unavailable — the same-product, same-vendor and same-CWE lists could not be loaded just now. That is not a sign that none exist; please retry shortly.

Frequently asked(5)

What is CVE-2025-7854?
CVE-2025-7854 is a high vulnerability published on July 19, 2025. A vulnerability classified as critical has been found in Tenda FH451 1.0.0.9. Affected is the function fromVirtualSer of the file /goform/VirtualSer. The manipulation of the argument page leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been…
When was CVE-2025-7854 disclosed?
CVE-2025-7854 was first published in the National Vulnerability Database on July 19, 2025, with the most recent update on June 17, 2026. EchelonGraph re-ingests CVE updates from NVD on a 2-hour cycle, so this page reflects the latest published state.
Is CVE-2025-7854 actively exploited?
CVE-2025-7854 is not currently on CISA's Known Exploited Vulnerabilities catalog. FIRST EPSS estimates a 1% probability of exploitation in the next 30 days, which ranks it in the top 37.6% of all scored CVEs.
What is the CVSS score of CVE-2025-7854?
CVE-2025-7854 has a CVSS v3 base score of 8.8 (NVD).
How do I remediate CVE-2025-7854?
Patch to the fixed version published by the affected vendor. Where vendor advisories exist for CVE-2025-7854, EchelonGraph cross-links them in the Vendor Advisories panel below — those typically contain the canonical remediation steps, fixed version numbers, and any vendor-specific mitigations.

Dependency Blast Radius

Explore the affected products and dependency analysis for CVE-2025-7854

Explore →

Is Your Infrastructure Affected by CVE-2025-7854?

EchelonGraph automatically scans your cloud infrastructure and maps CVE exposure using blast radius analysis.